Pramac ES8000 6.6kW 400V 3PH Petrol Generator

£1,153.33

Key features:

  • Selector switch: OFF – ON
  • Starting systems: Recoil
  • Fuel Cock
  • Thermal protection
  • Oil guard
  • SCHUKO 230V 16A IP54 Socket x 1
  • 2P+T CEE 230V 16A IP44 Socket x 1
  • 3P+N+T CEE 400V 16A IP44 Socket x 1

Pramac ES8000 6.6kW 400V 3PH Petrol Generator

A petrol generator designed specifically for intensive operations where performance power is demanded by professional user, over an extended period of time.

  • Selector switch: OFF – ON
  • Starting systems: Recoil
  • Fuel Cock
  • Thermal protection
  • Oil guard
  • SCHUKO 230V 16A IP54 Socket x 1
  • 2P+T CEE 230V 16A IP44 Socket x 1
  • 3P+N+T CEE 400V 16A IP44 Socket x 1

Optional Accessories

Supplements Control
Electrical box DPP + HM. Extra Protection with:

  • Differential protection 30mA
  • Circuit breaker
  • Hourmeter

Transportation Kit:

  • with fixed handles; or
  • with folding handles
Brand

Pramac

Model

ES8000 400V

Engine

Honda

Phase

Three

Voltage

230-240VAC, 400-415VAC

Rating

6-20kVA

Application

Commercial, Industrial, Site Power, Standby Power

Fuel

Petrol

Start

Recoil

Specifications

Main Features

Frequency50Hz
Voltage400/230V
Power factor0.8 cos ϕ
Phase3

Power Rating

Emergency Standby Power ESP8.3 kVA
Emergency Standby Power ESP6.6 kW
Continuous power COP7.0 kVA
Continuous power COP5.6 kW

Single Phase Power Rating

Single phase Maximum Power4.0 kVA
Single phase continuous power COP3.7 kW

Ratings definition (ISO-8528)

ESP – Emergency Standby Power:
It is the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 h of operation per year with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. The permissible average power output over 24 h of operation shall not exceed 70 % of the ESP.
COP – Continuous Power:
It is defined as being the maximum power which a generating set is capable of delivering continuously for an unlimited number of hours, with the maintenance intervals and procedure being carried out as prescribed by the manufacturers.

Engine Specifications

Engine BrandHonda
ModelGX390 Recoil
Engine cooling systemAir
Displacement389 cm³
AspirationNatural
Operating Speed-Nominal3000 rpm
Speed governorMechanical
FuelPetrol
Oil capacity1.1 l
Starting systemRecoil

Alternator Specifications

TypeBrushes
ClassH
IP protection23
Poles2
Frequency50 Hz
Voltage tolerance6 %
Voltage regulation systemCompound

Dimensions

Length729 mm
Width500 mm
Height536 mm
Dry weight81 kg
Fuel tank capacity11 l

Autonomy

Fuel consumption at 75% of Load2.15 l/h
Fuel consumption at 100% of Load2.86 l/h
Running time at 75% of load5.12 h
Running time at 100% of load3.85 h

Noise Level

Guaranteed noise level (LWA)97 dB(A)
Noise pressure level @ 7 m69 dB(A)
Scroll to Top